 comp.dcom.telecom.tech  Post an article  get this group's latest topics as an RSS feed add this group's latest topics to your My MSN content add this group's latest topics to your My Yahoo content  add this group's latest topics to your Google content  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Worrisome Dmarc Wiring KyleAK 03-22-2007
Posted by on March 22, 2007, 12:53 pm
If you were  Registered and logged in, you could reply and use other advanced thread options


I recently encountered a customer with a Dmarc and associated wiring
that has me a little worried. Here is a photo of the area:

http://www.digitalsonance.com/dmarc.jpg

I was standing in a pool of water when I took the photo (for some
reason there are drainage issues on that side of the building). None
the less, the amount of exposed wiring and the Telco's choice of
location for the NIU for the customer's T1 data line are a bit
frustrating. My worry is that weather (or someone with a pair of wire
cutters) could do a significant amount of damage that could bring our
operations down some day.

I already know I need to completely rewire from the Dmarc back to our
wiring closet (the wiring is old and in much need of replacement after
being weathered for so long), but I'd like to get all this taken care
of in one shot. Does anyone have any suggestions as to the best way
to remedy this situation?

Thanks.


NMFall 20%
Posted by Doug McIntyre on March 22, 2007, 6:22 pm
If you were  Registered and logged in, you could reply and use other advanced thread options


KyleAK@gmail.com writes:
>I recently encountered a customer with a Dmarc and associated wiring
>that has me a little worried. Here is a photo of the area:
>http://www.digitalsonance.com/dmarc.jpg


This doesn't look too different than tens of thousands of other
installations..


>I was standing in a pool of water when I took the photo (for some
>reason there are drainage issues on that side of the building). None
>the less, the amount of exposed wiring and the Telco's choice of
>location for the NIU for the customer's T1 data line are a bit
>frustrating. My worry is that weather (or someone with a pair of wire
>cutters) could do a significant amount of damage that could bring our
>operations down some day.

The NIU would be built for the weather.

Its all about how much you want to spend to get your peace of mind.

The ultimate would be to pay electricians/Qwest to move the demarc
inside the building. This sort of job would probably start around $2-3k
and go up from there though.

They'd probably want 4" conduit to go back to the handhole/manhole,
and then you could move your arrestor block panel & NIU inside, and
rewire it all.

Next level down would be to put your exposed wiring into some conduit.
Electrician could probably do that for some $hundreds. Looks like the
original electrician snuck the wire in around some water pipe, get
some decent conduit through the wall and up to the panel.

The demarc is the responsibility of the building owner though, not Qwest..

If things are super critical though, you may want to think redundancy,
although in this case, it might not make alot of sense.


Posted by Rod H on March 24, 2007, 7:18 am
If you were  Registered and logged in, you could reply and use other advanced thread options



>I recently encountered a customer with a Dmarc and associated wiring
> that has me a little worried. Here is a photo of the area:
>
> http://www.digitalsonance.com/dmarc.jpg
>
> I was standing in a pool of water when I took the photo (for some
> reason there are drainage issues on that side of the building). None
> the less, the amount of exposed wiring and the Telco's choice of
> location for the NIU for the customer's T1 data line are a bit
> frustrating. My worry is that weather (or someone with a pair of wire
> cutters) could do a significant amount of damage that could bring our
> operations down some day.
>
> I already know I need to completely rewire from the Dmarc back to our
> wiring closet (the wiring is old and in much need of replacement after
> being weathered for so long), but I'd like to get all this taken care
> of in one shot. Does anyone have any suggestions as to the best way
> to remedy this situation?
>
> Thanks.
>

I agree with doug. this is typical. get a piece of conduit and attatch it
to the building. you should be able to find something at your local
hardware store. I assume that your actual d'marc is the smaller box on top
in the pix. is that a padlock i see.




Similar ThreadsPosted
66 Block wiring question October 23, 2007, 7:50 pm
DSL Splitter - house wiring question(s) October 12, 2008, 4:26 pm

other useful resources:
The Federal Communications Commission (FCC)
Telecommunications Industry Association
Electronic and Software Security Products and Services
International Telecommunication Union

Custom CGI Perl and PHP programming by 1-Script.com

Contact Us | Privacy Policy
The site map in XML format XML site map