Posted by on November 8, 2006, 12:45 pm
If you were Registered and logged in, you could reply and use other advanced thread options
I run the computers at a small school near Edmonton, Alberta, Canada
Recently I was given a set of Superstack 2 switches, one with a matrix
module.
I found matrix cables on ebay.
Having my switches work as a single unit has made logins work much
better.
This morning however I had an wierd event.
Two switches dropped offline. From the master switch, doing
system->inventory showed units 1 and 4 as operational, but units 2 and
3 were absent. Doing a system reset did nothing. Doing a power cycle
fixed the problem, but I don't know what just happened, nor why.
What do I need to look for to determine what just happened?
***
Second event: I have spanning tree disabled, because enabling it means
that computers doing a PXE boot don't get a response to their dhcp
request. If that fails, and they boot off the local hard disk, the
dhcp request that comes when the OS boots works just fine.
I would like to put in some redundent links between switches, but with
STP this is a noshow. What is my best solution to have PXE work, along
with spanning tree?
|