Posted by M.C. van den Bovenkamp on July 28, 2005, 5:11 pm
If you were Registered and logged in, you could reply and use other advanced thread options
ntstech@gmail.com wrote:
> I have a Catalyst 4507 and several 3750's with 1000BASE-SX, 100BASE-FX,
> and 1000BASE-T intefaces that I want to set up in a lab so I can start
> testing and configuring them. I am thinking of purchasing some
> Multimode fiber optic patch cables, 6' and I am wondering if there will
> be any problem with the switches being so close to eachother or if
> there is anything I need to look out for.
Shouldn't be a problem. You might overdrive LX modules with patch cables
that short, but SX and 100BASE-FX have no such issues.
Regards,
Marco.
|