Posted by Dave on April 1, 2005, 2:03 pm
If you were Registered and logged in, you could reply and use other advanced thread options
I think you meant to say that the SNR should be >35 (greater than 35).
> Those numbers are well within the operating range of a cable modem. Cable
> modems are designed to wrok with an inout window of -15 - +15dBmV, and an
> output of 8 - 55dBmV. SNR is excellent -- supposed to be <35dB.
>
> (More below)
>
>
> Rick Kunath wrote:
>
>> Thec wrote:
>>
>>
>>>Now that the weather ambientming warmer with each day, I have noticed
>>>that
>>>the downstream power level to my cable modem is beginning to decrease.
>>>The warm weather also is causing my cable modem to increase it's upstream
>>>power
>>>level as well. The SNR is also slightly decreasing with warmer weather.
>>>During the very cold nights last winter, I was seeing SNR at around 38
>>>and. With the warm days now (currenty 80 degrees), the SNR is between 35
>>>and 36. Downstream power has gone from -3.5 and -4 dBmV to between -7 and
>>>-8 dBmV. Upstream power has gone from 42 dBmV to 45 dBmV. Everything
>>>still
>>>looks well within specs, but I'm concerned that it may pass the
>>>thresholds
>>>once the 90+ degree temperature arrives.
>>>
>>
>>
>> The cable plant losses increase as the ambient temperature rises. Cable
>> plants work best cold. The active devices in the cable company's plant
>> have
>> correction circuitry to compensate for this. ALC (automatic level
>> control)
>> holds the output level of an active device constant and ASC (automatic
>> slope control) holds the pre-emphasis level constant. Cable plant active
>> devices pre-emphasize the higher frequencies of the baseband because of
>> the
>> higher loss of the coaxial hardline as frequency increases. This "slope"
>> as
>> it is called allows the downstream active device to see a flat (or nearly
>> so) frequency response on the baseband. Since the loss of hardline
>> changes
>> with increasing temperature, the ALC and ASC circuitry automatically
>> increases the gain and slope as appropriate to maintain a constant level
>> to
>> the next downstream active device. This is adjustable, and may be
>> operating
>> incorrectly in your case.
>>
>>
>>>As a recent test (while 80 degrees outside), I ran the
>>>cable line coming in directly to the modem to see what the downstream was
>>>and it was a solid +1 dBmV.
>>
>>
>> This is pretty low, though legal. I'd expect to see +15 dBm in a properly
>> set up and designed system at your demarcation point.
>
> Not low -- perfect. Cable modems operate within a window of -15 -
> +15dBmV. Much above or below that and sync goes away. With +15dBmV
> (15dBm would be ~+63dBmV) at the groundblock, as the levels fluctuate
> connectivity would be intermittent.
>
> Most CATV systems in the US design their systems to have 15-20dBmV at the
> tap, which would typically be ~10-17dBmV at the groundblock. 64 QAM
> carriers run at 10dB down fron the nearest analog carrier, which means
> that at a groundblock that has +11dBmV as read by a regular Signal level
> meter, the cable modem would read +1dBmV. 256 QAM is 6dB down from
> analog.
>
> Even with +15dBmV at the groundblock, a 2-way splitter for the cable modem
> connection, and the outlet 50' from the splitter, the cable modem would
> read 2.1dBmV (256 QAM) or -2.1dBmV (64 QAM).
>>
>>
>>>I then ran it through the splitter (plus a three foot section of my own
>>>RG6) and got -2.5 dBmV.
>>
>>
>> Good so far.
>>
>>
>>>I then added the coupler to the splitter,
>>
>>
>> Describe the coupler? What kind of device is this?
>>
>>
>>>I then ran it through the surge protector, which seems to introduce
>>>another
>>>2.5 dB of attenuation.
>>
>>
>> Dump the surge supressor. Get yourself a Regal gas-discharge ground
>> block,
>> and place this at the demarcation point.
>>
>> As to cable plant signal level variations, expect some change, but the
>> changes you are reporting would indicate that your plant is incorrectly
>> set
>> up or has incorrectly operating ASC/ALC circuitry.
>>
>> Call your cable company and have them send out a line tech to take a look
>> at
>> their plant.
>>
>> Rick Kunath
>
>
> CIAO!
>
> Ed N.
|