Posted by MC on March 26, 2007, 4:48 pm
If you were Registered and logged in, you could reply and use other advanced thread options Dophi wrote:
>> I just added a 470 24 port switch to my existing 3 switch (450 series)
>> configuration, the three 450's continue to work ok but the 470 doies
>> not the Cas UP / Dn lights just blink all the time and they dont on
>> the others. All I did is reset my 470 to defaults and cascade connect
>> it. is that correct or do i do sonmething else?
>
> There are something you should be aware.
> 1. Software version of 450 should be 4.5.0.6 or higher.
> 2. BayStack 450 can't be base unit in a mixed stack.
> 3. A mixed stack cannot contain both a BayStack 450 and a BayStack
> 470-48T unit.
>
the previous post is all true also, and forgot about all that myself.
Also, I have had more issues with a mixed stack.
I try and run pure stacks of same models these days.
|